set system login
3-4 Basic Configuration
set system login
Usethiscommandtocreateanewuserloginaccount,ortodisableorenableanexistingaccount.
TheEnterasysB5switchsupportsupto16useraccounts,includingtheadminaccount,which
cannotbedeleted.
Syntax
set system login username {super-user | read-write | read-only} {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,superuser.
Usage
Loginaccounts,includingtheadminuseraccount,canbelockedoutaftermultiplefailedattempts
tologintothesystem.Refertoshowsystemlockoutonpage37andsetsystemlockouton
page38formoreinformationaboutlockoutparameters.
Iftheadminuseraccount
hasbeenlockedout,youmustwaituntiltheconfiguredlockouttime
periodhasexpiredoryoucanpowercycletheswitchtorebootit,whichwillreenabletheadmin
useraccount.
Example
Thisexampleshowshowtoenableanewuseraccountwiththeloginname“netops”withsuper
useraccessprivileges:
B5(su)->set system login netops super-user enable
clear system login
Usethiscommandtoremovealocalloginuseraccount.
Syntax
clear system login username
Parameters
username Specifiesaloginnameforaneworexistinguser.Thisstringcanbea
maximumof80characters,althoughamaximumof16charactersis
recommendedforproperviewingintheshowsystemlogindisplay.
superuser|
readwrite|
readonly
Specifiestheaccessprivilegesforthi suser.
enable
|disable Enablesordisablestheuseraccount.
username Specifiestheloginnameoftheaccounttobecleared.
Note: The default admin (su) account cannot be deleted.