Configuring Cisco Discovery Protocol
Enterasys B5 CLI Reference 6-7
Configuring Cisco Discovery Protocol
Purpose
ToreviewandconfiguretheCiscodiscoveryprotocol.Discoveryprotocolsareusedtodiscover
networktopology.Whenenabled,theyallowCiscodevicestosendperiodicPDUsabout
themselvestoneighboringdevices.Specifically,thisfeatureenablesrecognizingPDUsfromCisco
phones.Atableofinformationaboutdetectedphonesiskeptbythe
switchandcanbequeriedby
thenetworkadministrator.
Commands
ThecommandsusedtoreviewandconfiguretheCiscodiscoveryprotocolarelistedbelow.Refer
alsotoshowneighborsonpage66.
show ciscodp
UsethiscommandtodisplayglobalCiscodiscoveryprotocolinformation.
Syntax
show ciscodp
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayglobalCiscoDPinformation.
B5(su)->show ciscodp
CiscoDP :Enabled
Timer :5
Holdtime (TTl): 180
For information about... Refer to page...
show ciscodp 6-7
show ciscodp port info 6-8
set ciscodp status 6-9
set ciscodp timer 6-9
set ciscodp holdtime 6-10
set ciscodp port 6-10
clear ciscodp 6-12

Table of Contents