EasyManua.ls Logo

Enterasys b5

Enterasys b5
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disabling / Enabling and Naming Ports
Enterasys B5 CLI Reference 7-7
Sincerunningthecablediagnosticsmaymomentarilyinterruptpacketflow,awarningmessageis
displayedandyouarepromptedtocontinue.
Example
Thisexampleshowsthecablestatusforportge.1.1.
B5(su)->show port cablestatus ge.1.1
Warning: port(s) will be offline momentarily.
Do you want to continue (y/n) [n]?y
Port Status Length
--------- --------- -------
ge.1.1 Normal 3(m)-5(m)
Table 73providesanexplanationofthecommandoutput.
Disabling / Enabling and Naming Ports
Purpose
Todisableandreenableoneormoreports,andtoassignanaliastoaport.Bydefault,allportsare
enabledatdevicestartup.Youmaywanttodisableportsforsecurityortotroubleshootnetwork
issues.Portsmayalsobeassignedanaliasforconvenience.
Commands
Table 7-3 show port cablestatus Output Details
Output Field What it displays...
Port Lists the port designation.
Status Indicates the status of the port. The value is one of the following:
Normal = normal
Open = no cable attached to port
Short = detection of an inter-pair short
Fail = unknown error or crosstalk
Detach = indicates ports on stack units that are no longer present,
but were previously connected
Not Supported = ports other than 1GE RJ45 ports
Length Indicates the approximate length of the cable attached to the port.
For information about... Refer to page...
set port disable 7-8
set port enable 7-8
show port alias 7-9
set port alias 7-9

Table of Contents