ip irdp holdtime
Enterasys B5 CLI Reference 20-13
Example
ThisexampleshowshowtosettheminimumIRDPadvertisementinterval to500secondsonthe
VLAN1interface:
B5(su)->router(Config)#interface vlan 1
B5(su)->router(Config-if(Vlan 1))#ip irdp minadvertinterval 500
ip irdp holdtime
UsethiscommandtosetthelengthoftimeinsecondsIRDPadvertisementsareheldvalid.Theno
formofthiscommandresetstheholdtimetothedefaultvalueofthreetimesthe
maxadvertintervalvalue,whichisequalto1800seconds.
Syntax
ip irdp holdtime holdtime
no irdp holdtime
Parameters
Defaults
None.
Mode
Interfaceconfiguration:B5(su)>router(Configif(Vlan1))#
Example
ThisexampleshowshowtosettheIRDPholdtimeto4000secondsontheVLAN1interface:
B5(su)->router(Config)#interface vlan 1
B5(su)->router(Config-if(Vlan 1))#ip irdp holdtime 4000
ip irdp preference
UsethiscommandtosettheIRDPpreferencevalueforaninterface.ThisvalueisusedbyIRDPto
determinetheinterface’sselectionasadefaultgatewayaddress.Thenoformofthiscommand
resetstheinterface’sIRDPpreferencevaluetothedefaultof0.
Syntax
ip irdp preference preference
no irdp preference
Parameters
holdtime Specifiestheholdtimeinseconds.Validvaluesare0to
9000.
preference Specifiesthevaluetoindicatetheinterface’suseasadefaultrouter
address.Validvaluesare2147483648to2147483647.
Theminimumvalueindicatesthattheaddress,eventhoughitmaybe
advertised,isnottobeusedbyneighboringhostsasadefaultrouter
address.