show spantree operedge
Enterasys B5 CLI Reference 9-41
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresetge.1.11asanonedgeport:
B5(su)->clear spantree adminedge ge.1.11
show spantree operedge
UsethiscommandtodisplaytheSpanningTreeedgeportoperatingstatusforaport.
Syntax
show spantree operedge [port port-string]
Parameters
Defaults
Ifportstringisnotspecified,edgeportoperatingstatuswillbedisplayedforallSpanningTree
ports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.2.7:
B5(rw)->show spantree operedge port ge.2.7
Port ge.2.7 has a Port Oper Edge of Edge-Port
portstring Specifiesport(s)onwhichtoresetedgeportstatus.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 71.
portportstring Displaysedgeportoperatingstatusforspecificport(s).