set ciscodp holdtime
6-10 Discovery Protocol Configuration
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheCiscoDPtimerto120seconds.
B5(su)->set ciscodp timer 120
set ciscodp holdtime
Usethiscommandtosetthetimetolive(TTL)forCiscodiscoveryprotocolPDUs.Thisisthe
amountoftime,insecond s,neighboringdeviceswillholdPDUtransmissionsfromthesending
device.
Syntax
set ciscodp holdtime hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCiscoDPholdtimeto180seconds:
B5(su)->set ciscodp hold-time 180
set ciscodp port
Usethiscommandtosetthestatus,voiceVLAN,extendedtrustmode,andCoSpriorityfor
untrustedtrafficfortheCiscoDiscoveryProtocolononeormoreports.
Syntax
set ciscodp port {[status {disable | enable}] [vvid {vlan-id | none | dot1p |
untagged}] [trusted {yes | no}] [cos value]} port-string
seconds SpecifiesthenumberofsecondsbetweenCiscoDPPDUtransmissions.
Validvaluesarefrom5to254seconds.
holdtime SpecifiesthetimetoliveforCiscoDPPDUs.Validvaluesarefrom10to255
seconds.