22-38 Authentication and Authorization Configuration
show multiauth
Usethiscommandtodisplaymultipleauthenticationsystemconfiguration.
Syntax
show multiauth
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaymultipleau thenticationsystemconfiguration:
B5(rw)->show multiauth
Multiple authentication system configuration
-------------------------------------------------
Supported types : dot1x, pwa, mac
Maximum number of users : 768
Current number of users : 2
System mode : multi
Default precedence : dot1x, pwa, mac
Admin precedence : dot1x, pwa, mac
Operational precedence : dot1x, pwa, mac
clear multiauth port 22-42
show multiauth station 22-43
show multiauth session 22-43
show multiauth idle-timeout 22-44
set multiauth idle-timeout 22-45
clear multiauth idle-timeout 22-46
show multiauth session-timeout 22-46
set multiauth session-timeout 22-47
clear multiauth session-timeout 22-48