set sflow receiver owner
Enterasys B5 CLI Reference 24-7
set sflow receiver owner
Usethiscomm andtoconfiguretheowneridentitystringandtimeoutvalueforansFlowCollector
intheswitch’ssFlowReceiversTable.
Syntax
set sflow receiver index owner owner-string timeout timeout
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Usage
InorderforansFlowCollectortobeassignedtoreceivesampledatagramsfromthesFlowAgent
ontheswitch,an entryforthatCollectormustbeconfiguredintheswitch’ssFlowReceiversTable.
Anentrymustcontainanowneridentitystring,anon‐zerotimeoutvalue,andtheIPaddress
of
theCollector.ConfiguretheIPaddresswiththesetsflowreceiveripcommand.
Anentrywithoutanowneridentitystringisconsideredunclaimedandcannotbe assignedasa
receivertosamplerorpollerinstances.
Oncethetimersetbythiscommandexpires,thereceiver/Collectorandallthesamplersand
pollersassociatedwiththisCollectorexpireandareremovedfromtheswitch’sconfiguration.In
ordertostartsendingsampledatatotheCollectoragain,theCollectormustbereconfiguredwith
anewtimeoutvalueandsamplersandpollersmustbeconfiguredagain.Therefore,youshould
considersettingthetimeoutvalueto
thelargestvaluethatisreasonableforyourenvironment.
Example
Thisexampleconfiguresanentryforindex1inthesFlowReceiversTable.
B5
(su)->set sflow receiver 1 owner ets1 timeout 180000
set sflow receiver ip
UsethiscommandtoconfiguretheIPaddressofansFlowCollectorintheswitch’ssFlow
ReceiversTable.
Syntax
set sflow receiver index ip ipaddr
index IndexnumberinthesFlowReceiversTableforthereceiver/Collector
beingconfigured.Theindexcanrangefrom1to8.
ownerowner‐string Theidentitystringofthereceiver/Collectorbeingconfigured.
Thestringcanbeupto127charactersinlength.
timeouttimeout Thetime,inseconds,remaining beforethereceiver/Collector
being
configuredandallassociatedsamplersandpollersexpire.
Thevaluecanrangefrom0to4294967295seconds.