show dot1x auth-config
Enterasys B5 CLI Reference 22-17
show dot1x auth-config
Usethiscommandtodisplay802.1Xauthenticationconfigurationsettingsforoneormoreports.
Syntax
show dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod]
[port-string]
Parameters
Defaults
Ifnoparametersarespecified,all802.1Xsettingswillbedisplayed.
Ifportstringisnotspecified,informationforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Examples
ThisexampleshowshowtodisplaytheEAPOLportcontrolmodeforge.1.1:
B5(su)->show dot1x auth-config authcontrolled-portcontrol ge.1.1
Port 1: Auth controlled port control: Auto
Thisexampleshowshowtodisplaythe802.1Xquietperiodsettingsforge.1.1:
B5(su)->show dot1x auth-config quietperiod ge.1.1
Port 1: Quiet period: 30
Thisexampleshowshowtodisplayall802.1Xauthenticationconfigurationsettingsforge.1.1:
B5(ro)->show dot1x auth-config ge.1.1
authcontrolled
portcontrol
(Optional)DisplaysthecurrentvalueofthecontrolledPortcontrol
parameterfortheport.
maxreq (Optional)Displaysthevaluesetformaximumrequestscurrentlyinuseby
thebackendauthenticationstatemachine.
quietperiod (Optional)Displaysthevaluesetforquietperiodcurrentlyinusebythe
authenticatorPAEstatemachine.
reauthenabled (Optional)
Displaysthestateofreauthenticationcontrolusedbythe
ReauthenticationTimerstatemachine.
reauthperiod (Optional)Displaysthevalue,inseconds,setforthereauthentication
periodusedbythereauthenticationtimerstatemachine.
servertimeout (Optional)Displaystheservertimeoutvalue,inseconds,currentlyinuse
bythebackendauthenticationstatemachine.
supptimeout (Optional)Displaysthe
authenticationsupplicanttimeoutvalue,in
seconds,currentlyinusebythebackendauthenticationstatemachine.
txperiod (Optional)Displaysthetransmissionperiodvalue,inseconds,currentlyin
usebytheauthenticatorPAEstatemachine.
portstring (Optional)Limitsthedisplayofdesiredinformationinformationtospecific
port(s).Foradetaileddescriptionofpossible
portstringvalues,referto
PortStringSyntaxUsedintheCLIonpage 71.