ip irdp maxadvertinterval
20-12 IPv4 Routing Protocol Configuration
ip irdp maxadvertinterval
UsethiscommandtosetthemaximumintervalinsecondsbetweenIRDPadvertisements.Theno
formofthiscommandresetsthemaximumadvertisementintervaltothedefaultvalueof600
seconds.
Syntax
ip irdp maxadvertinterval interval
no irdp maxadvertinterval
Parameters
Defaults
None.
Mode
Interfaceconfiguration:B5(su)>router(Configif(Vlan1))#
Example
ThisexampleshowshowtosetthemaximumIRDPadvertisementintervalto1000secondsonthe
VLAN1interface:
B5(su)->router(Config)#interface vlan 1
B5(su)->router(Config-if(Vlan 1))#ip irdp maxadvertinterval 1000
ip irdp minadvertinterval
Usethiscommandtosettheminimuminterva linsecondsbetweenIRDPadvertisements.Theno
formofthiscommanddeletesthecustomholdtimesetting,andresetstheminimum
advertisementintervaltothedefaultvalueofthreefourthsofthemaxadvertintervalvalue,which
isequalto450seconds.
Syntax
ip irdp minadvertinterval interval
no irdp minadvertinterval
Parameters
Defaults
None.
Mode
Interfaceconfiguration:B5(su)>router(Configif(Vlan1))#
interval Specifiesamaximumadvertisementintervalinseconds.Validvaluesare
4to1800.
interval Specifiesaminimumadvertisementintervalinseconds.Validvaluesare3
to1800.

Table of Contents