clear cos port-resource irl
Enterasys B5 CLI Reference 11-29
----------- -------- ---- ---- ---------- --------------- ------
2.0 1 irl kbps 10000 drop none
Thisexampledisplaysthefloodcontrolresourcesconfiguredfor group1.0.
B5(su)->show cos port-resource flood-ctrl 1.0
'?' after the rate value indicates an invalid rate value
Group Resource Type Unit Rate Rate Limit Action
Index type
--------- ----------- ---------- ---- ---------- --------------- ------
1.0 ucast flood-ctrl pps 20 drop none
1.0 mcast flood-ctrl pps 10 drop none
1.0 bcast flood-ctrl pps 5 drop none
clear cos port-resource irl
Usethiscommandtoclearinboundratelimitresourcestodefaultvalues.
Syntax
clear cos port-resource irl {all | group-type-index [irl-index [unit] [rate]
[type]]}
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleclearsthedatarateto0forIRLresourceindex1forgroup2.0.
B5(su)->clear cos port-resource irl 2.0 1 rate
all ClearallIRLresourcesforallportgroups.
group‐type‐index Specifiesaninboundratelimitingportgroup/typeindex.Validentriesare
intheformofgroup#.port‐type.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforport‐type
canrangefrom0to1,althoughonly
porttype0iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.
irl‐index (Optional)Inboundratelimiterresourceindexassociatedwiththe
specifiedportgroup.Validvaluesrangefrom0to99.
unit Cleartheunitofmeasurefortheinboundratelimiter.
rate Clearthe
datarateforthisinboundratelimiter.
type Cleartheactionfortheratelimiter.