clear mirror vlan
Enterasys B5 CLI Reference 7-43
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
RefertoRemotePortMirroringonpage738forinformationaboutconfiguringmirrorVLANs.
UsetheshowportmirroringcommandtodisplaytheVLANsconfiguredforremoteport
mirroring.
Example
ThefollowingexampleassignsaVLANformirroringtrafficandthenshowstheconfiguredport
mirroringwiththeshowportmirrorcommand.
B5(su)->set mirror vlan 2
B5(su)->show port mirroring
Port Mirroring
==============
Source Port = ge.1.1
Target Port = ge.1.10
Frames Mirrored = Rx and Tx
Port Mirroring status enabled
Mirror Vlan = 2
clear mirror vlan
UsethiscommandtocleartheVLANtobereservedformirroringtraffic.
Syntax
clear mirror vlan vlan-id
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThefollowingexampleclearsVLAN2frombeingusedforremoteportmirroring.
B5(su)->clear mirror vlan 2
vlanid SpecifiestheVLANtobecleared.TheIDcanrangefrom2to4093.