set rmon history
Enterasys B5 CLI Reference 15-7
Sample 2779 Interval Start: 1 days 0 hours 2 minutes 22 seconds
Drop Events = 0 Undersize Pkts = 0
Octets = 0 Oversize Pkts = 0
Packets = 0 Fragments = 0
Broadcast Pkts = 0 Jabbers = 0
Multicast Pkts = 0 Collisions = 0
CRC Align Errors = 0 Utilization(%) = 0
set rmon history
UsethiscommandtoconfigureanRMONhistoryentry.
Syntax
set rmon history index [port-string] [buckets buckets] [interval interval] [owner
owner]
Parameters
Defaults
Ifbucketsisnotspecified,themaximumnumberofentriesmaintainedwillbe50.
Ifnotspecified,intervalwillbesetto30seconds.
Ifownerisnotspecified,monitorwillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowconfigureRMONhistoryentry1onportge.2.1tosampleevery20
seconds:
B5(rw)->set rmon history 1 ge.2.1 interval 20
clear rmon history
UsethiscommandtodeleteoneormoreRMONhistoryentriesorresetoneormoreentriesto
defaultvalues.Forspecificvalues,refertosetrmonhistoryonpage 157.
Syntax
clear rmon history {index-list | to-defaults}
indexlist Specifiesanindexnumberforthisentry.
portstring (Optional)Assignsthisentrytoaspecificport.
bucketsbuckets (Optional)Specifiesthemaximumnumberofentriestomaintain.
intervalinterval (Optional)Specifiesthesamplingintervalinseconds.
ownerowner (Optional)Specifiesanownerforthisentry.