set sntp poll-interval
Enterasys B5 CLI Reference 14-33
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoremove theserveratIPaddress10.21.1.100 fromtheSNTPserverlist:
B5(su)->clear sntp server 10.21.1.100
set sntp poll-interval
Usethiscommandtosetthepollinterval betweenSNTPunicastrequests.
Syntax
set sntp poll-interval value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSNTPpollintervalto64seconds:
B5(su)->set sntp poll-interval 6
clear sntp poll-interval
UsethiscommandtoclearthepollintervalbetweenunicastSNTPrequests.
Syntax
clear sntp poll-interval
Parameters
None.
Defaults
None.
value Thepollintervalis2tothepower ofvalueinseconds,wherevaluecanrange
from6to10.