set lldp hold-multiplier
6-24 Discovery Protocol Configuration
B5(rw)->set lldp tx-interval 20
set lldp hold-multiplier
UsethiscommandtosetthetimetolivevalueusedinLLDPframessentbythisdevice.Thetime
toliveforLLDPDUdataiscalculatedbymultiplyingthetransmitintervalbytheholdmultipl ier
value.
Syntax
set lldp hold-multiplier multiplier-val
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransmitintervalto20secondsandtheholdmultiplierto5,whichwill
configureatimetoliveof100tobeusedintheTTL fieldintheLLDPDUheader.
B5(rw)->set lldp tx-interval 20
B5(rw)->set lldp hold-multiplier 5
set lldp trap-interval
Usethiscommandtosettheminimuminterva lbetweenLLDPnotificationssentbythisdevice.
LLDPnotificationsaresentwhenaremotesystemchangehasbeendetected.
Syntax
set lldp trap-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
multiplierval Sp ecifiesthemultipliertoapplytothetransmitintervaltodetermine
thetimetolivevalue.Valuecanrangefrom2to10 .Defaultvalueis4.
frequency S p ecifiestheminimumtimebetweenLLDPtraptransmissions,in
seconds.Thevaluecanrangefrom5to3600seconds.Thedefault
valueis5seconds.