EasyManua.ls Logo

Enterasys b5 - Show Lldp Port Local-Info

Enterasys b5
714 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
show lldp port local-info
6-18 Discovery Protocol Configuration
Defaults
Ifport‐stringisnotspecified,portlocationconfigurationinformationwillbedisplayedforall
ports.
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplayportlocationinformationforthreeports.
B5(ro)->show lldp port location-info ge.1.1-3
Ports Type Location
-------- ------------- -------------------------
ge.1.1 ELIN 1234567890
ge.1.2 ELIN 1234567890
ge.1.3 ELIN 1234567890
show lldp port local-info
Usethiscommandtodisplaythelocalsysteminformationstoredforoneormoreports.Youcan
usethisinformationtodetectmisconfigurationsorincompatibilitiesbetweenthelocalportand
theattachedendpointdevice(remoteport).
Syntax
show lldp port local-info [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,localsysteminformationwillbedisplayedforallports.
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplaythelocalsysteminformationstoredforportge.4.1.Table 6‐4
describestheoutputfieldsofthiscommand.
B5(rw)->show lldp port local-info ge.4.1
Local Port :
ge.4.1 Local Port Id: ge.4.1
--------------------
Port Desc : ... 1000BASE-TX RJ45 Gigabit Ethernet Frontpanel Port
Mgmt Addr : 10.21.64.100
Chassis ID : 00-E0-63-93-74-A5
Sys Name : LLDP PoE test Chassis
Sys Desc : Enterasys Networks, Inc.
Sys Cap Supported/Enabled : bridge,router/bridge
port‐string (Optional)Displayslocalsysteminformationforoneorarangeof
ports.