show ip route
Enterasys B5 CLI Reference 3-13
show ip route
UsethiscommandtodisplaytheIProutetable.
Syntax
show ip route
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowstheoutputofthiscommand.
B5(ro)->show ip route
INET route table
Destination Gateway Flags Use If Metric
0.0.0.0/0 192.168.0.1 UG 13 host 5
127.0.0.1 127.0.0.1 UH 0 lo0 5
192.168.0.0/24 127.0.0.1 UC 2 host 5
192.168.0.101 127.0.0.1 UH 0 lo0 5
show system
Usethiscommandtodisplaysysteminformation,includingcontactinformation,powerandfan
traystatusanduptime.
Syntax
show system
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaysysteminformation:
B5(su)->show system