set spantree lpwindow
Enterasys B5 CLI Reference 9-49
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventthresholdtothedefaultof3:
B5(rw)->clear spantree lpthreshold
set spantree lpwindow
UsethiscommandtosettheLoopProtecteventwindowvalueinseconds.
Syntax
set spantree lpwindow value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
TheLoopProtectWindowisatimervalue,inseconds,thatdefinesaperiodduringwhichLoop
Protecteventsarecounted.Thedefaultvalueis180seconds.Ifthetimerissetto0, theevent
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethreshold
isreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120seconds:
B5(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
value Specifiesthenumberofsecondsthatcomprisetheperiodduringwhich
LoopProtecteventsarecounted.Thedefaultev entwindowis180
seconds.