set sflow receiver port
Enterasys B5 CLI Reference 24-9
Example
Thisexamplesetsthemaximumdatagramsizeto2800bytesforindexentry1.
B5(su)->set sflow receiver 1 maxdatagram 2800
set sflow receiver port
UsethiscommandtoconfiguretheUDPportonthesFlowControllertowhichtheswitchwill
sendsampledatagrams.
Syntax
set sflow receiver index port port
Parameters
Defaults
Thedefaultportvalueis6343.
Mode
Switchcommand,read‐write.
Example
ThisexamplechangesthesFlowreceiverportontheCollectorto1234.
B5(su)->set sflow receiver 1 port 1234
clear sflow receiver
Usethiscommandtodeleteareceiver/CollectorfromthesFlowReceiversTable,ortoreturn
certainparameterstotheirdefaultvaluesforthespecifiedCollector.
Syntax
clear sflow receiver index [ip | maxdatagram | owner [timeout] | port]
Parameters
index IndexnumberinthesFlowReceiversTableforthereceiver/Collector
beingconfigured.Theindexcanrangefrom1to8.
portport SpecifiestheUDPportonthereceiver/Collectortowhichthesample
datagramsshouldbe sent.Bydefault,theportis6343.
index IndexnumberinthesFlowReceiversTableforthereceiver/Collector
beingconfigured.Theindexcanrangefrom1to8.
ip (Optional)CleartheIPaddress.
maxdatagram (Op tional)Returnthemaximumdatagramsizeto1400bytes.
owner (Optional)Cleartheowneridentitystring.EntriesinthesFlowReceiver
Tablewithoutanidentitystring
areconsideredunclaimed.
timeout (Optional)Clearthetimeoutvalueofthespecifiedentry.