11-32 Policy Classification Configuration
Ifaspecificportgroupisnotspecified,informationfor allportgroupsisdisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowstheClassofServiceIRLreferencesforportgroup1.0.Notethatnotallofthe
100possiblereferencesaredisplayedinthisoutputexample.
B5(su)->show cos reference irl 1.0
Group Index Reference Type Rate Limiter
----------- --------- ---- ------------
1.0 0 irl none
1.0 1 irl 1
1.0 2 irl none
1.0 3 irl none
...
1.0 97 irl none
1.0 98 irl none
1.0 99 irl none
clear cos reference
UsethiscommandtocleartheClassofServiceinboundratelimitingreferenceconfiguration.
Syntax
clear cos reference irl {all | group-type-index reference}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtocleartheCoSinboundratelimitingreferenceconfigurationfor all
groups:
B5(su)->clear cos reference irl all
irl SpecifiesthatIRLreferencesarebeingcleared.
all Clearallgroupsindexesandreferences.
grouptypeindex Specifiesan inboundratelimitingportgroup/typeindex.Validentriesare
intheformofgroup#.porttype.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforporttype
canrange
from0to1,althoughonlyporttype0iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.
reference Clearaspecificreferenceforthespecifiedportgroup.