EasyManuals Logo

Enterasys b5 User Manual

Enterasys b5
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #607 background imageLoading...
Page #607 background image
set dot1x auth-config
Enterasys B5 CLI Reference 22-19
set dot1x auth-config
Usethiscommandtoconfigure802.1Xauthentication.
Syntax
set dot1x auth-config {[authcontrolled-portcontrol {auto | forced-auth |
forced-unauth}] [maxreq value] [quietperiod value] [reauthenabled {false | true}]
[reauthperiod value] [servertimeout timeout] [supptimeout timeout] [txperiod
value]} [port-string]
Parameters
Defaults
Ifportstringisnotspecified,authenticationparameterswillbesetonallports.
Mode
Switchcommand,readwrite.
authcontrolled
portcontrol
auto|forcedauth|
forcedunauth
Specifiesthe802.1Xportcontrolmode.
autoSetportcontrolmodetoautocontrolledportcontrol.This
isthedefaultvalue.
forcedauthSetportcontrolmodetoForcedAuthorized
controlledportcontrol.
forcedunauthSetport
controlmodetoForcedUnauthorized
controlledportcontrol.
maxreqvalue Specifiesthemaximumnumberofauthenticationrequestsallowed
bythebackendauthenticationstatemachine.Validvaluesare110.
Defaultvalueis2.
quietperiodvalue Specifiesthetime(inseconds)followingafailedauthentication
beforeanotherattemptcanbemadebythe
authenticatorPAEstate
machine.Validvaluesare065535.Defaultvalueis60seconds.
reauthenabledfalse|
true
Enables(true)ordisables( false)reauthenticationcontrolofthe
reauthenticationtimerstatemachine.Defaultvalueisfalse.
reauthperiodvalue Specifiesthetimelapse(inseconds)betweenattemptsbythe
reauthenticationtimer
statemachinetoreauthenticateaport.Valid
valuesare065535.Defaultvalueis3600seconds.
servertimeouttimeout Specifiesatimeoutperiod(inseconds)fortheauthenticationserver,
usedbythebackendauthenticationstatemachine.Validvaluesare1
300.Defaultvalueis30seconds.
supptimeouttimeout Specifiesa
timeoutperiod(inseconds)fortheauthentication
supplicantusedbythebackendauthenticationstatemachine.Valid
valuesare1300.Defaultvalueis30seconds.
txperiodvalue Specifiestheperiod(inseconds)whichpassesbetweenauthenticator
PAEstatemachineEAPtransmissions.Validvaluesare065535.
Defaultvalue
is30seconds.
portstring (Optional)Limitstheconfigurationofdesiredsettingstospecified
port(s).Foradetaileddescriptionofpossibleportstringvalues,refer
toPortStringSyntaxUsedintheCLIonpage 7 1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys b5 and is the answer not in the manual?

Enterasys b5 Specifications

General IconGeneral
BrandEnterasys
Modelb5
CategoryOther
LanguageEnglish