EasyManua.ls Logo

Enterasys b5

Enterasys b5
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
clear spantree lpwindow
9-50 Spanning Tree Configuration
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectwindowvalue:
B5(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
clear spantree lpwindow
UsethiscommandtoresettheLoopProtecteventwindowtothedefaultvalueof180seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventwindowtothedefaultof180seconds:
B5(rw)->clear spantree lpwindow
set spantree lptrapenable
UsethiscommandtoenableordisableLoopProtecteventnotification.
Syntax
set spantree lptrapenable {enable | disable}
Parameters
enable|disable EnablesordisablesthesendingofLoopProtecttraps.Defaultis
disabled.

Table of Contents