EasyManua.ls Logo

Enterasys b5

Enterasys b5
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
clear snmp targetaddr
8-28 SNMP Configuration
Defaults
Ifnotspecified,udpportwillbesetto162.
Ifnotspecified,maskwillbesetto255.255.255.255
Ifnotspecified,timeoutwillbesetto1500.
Ifnotspecified,numberofretrieswillbesetto3.
Iftaglistisnotspecified,nonewillbeset.
Ifnotspecified,storagetype
willbenonvolatile.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoconfigureatrapnotificationcalledTrapSink.”Thistrapnotification
willbesenttotheworkstation192.168.190.80(whichistargetaddress“tr”).Itwillusesecurity
andauthorizationcriteriacontainedinatargetparametersentrycalled“v2cExampleParams”.For
moreinformationonconfiguringabasicSNMPtrap,
refertoCreatingaBasicSNMPTrap
Configurationonpage 836:
B5(su)->set snmp targetaddr tr 192.168.190.80 param v2cExampleParams taglist
TrapSink
clear snmp targetaddr
UsethiscommandtodeleteanSNMPtargetaddressentry.
Syntax
clear snmp targetaddr targetAddr
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
taglisttaglist (Optional)SpecifiesalistofSNMPnotifytagvalues.Thistagsalocation
tothetargetaddressasaplacetosendnotifications.Listmustbe enclosed
inquotesandtagvaluesmustbeseparatedbyaspace(forexample,
“tag1tag2”).
volatile|
nonvolatile
(Optional)Specifiestemporary(default),orpermanentstorageforSNMP
entries.
targetAddr Specifiesthetargetaddressentrytodelete.