show cos reference
Enterasys B5 CLI Reference 11-31
Defaults
None.
Mode
Switchcommand,read‐write.
Usage
TheCoSreferencetablemapstheuser‐definedIRLreferencesfoundintheCoSsettingstable(s ee
“setcossetting s”onpage 11‐21)toratelimiterscreatedintheportresourcetable(see“setcos
port‐resourceirl”onpage 11‐26).TheCoSreferencetableindexescanbethought
ofasvirtualrate
limiters.Thetableaccountsforthemaximumnumberofratelimiterssupportedbythedevice.
Thevirtuallimitersthenmaptothephysicalratelimiters.TheCoSIRLReferenceTableisnot
configuredbydefault.
TheCoSIRLreferencetableuses100indexesorvirtualratelimiters,
andmapseachvirtuallimiter
toaphysicallimiterorresource.AnIRLreferencetableexistsforeachportgroupconfigured,and
isindexedsimilarlytoportresources,asportgroup#,port‐type,reference.IRLreferencesarenot
populatedwithlimiters(resources),butcanbeconfiguredbytheuser.The
IRLreferencetablecan
bedisplayedusingtheshowcosreferencecommand.
Example
IntheCoSIRLreferencemappingtableforportgroups1.0and2.0,createareferencefortheIRL
resourcenumber1createdforeachgroup.Thereferencenumber1isused.
B5(su)->set cos reference irl 1.0 1 rate-limit 1
B5(su)->set cos reference irl 2.0 1 rate-limit 1
show cos reference
UsethiscommandtoshowtheClassofServiceinboundratelimitingreferenceconfiguration.
Syntax
show cos reference [irl [group-type-index]]
Parameters
Defaults
Ifirlisnotspecified,allCoSreferenceinformationisdisplayed.
reference IRLreferencenumberassociatedwiththisentry.
rate‐limitirl‐index Rate limiter(IRLresourceindex)tobindthisreferenceto.Validvalues
rangefrom0to99.
irl (Optional)Specifiesthatinboundratelimitingreferenceinformation
shouldbedisplayed.
group‐type‐index (Optional)Specifiesaninboundratelimitingportgroup/typeindex.Valid
entriesareintheformofgroup#.port‐type.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforport‐type
canrangefrom0
to1,althoughonlyporttype0iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.