show multiauth port
Enterasys B5 CLI Reference 22-41
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoclearthemultipleauthenticationprecedence:
B5(rw)->clear multiauth precedence
show multiauth port
Usethiscommandtodisplaymultipleauthenticationpropertiesforoneormoreports.
Syntax
show multiauth port [port-string]
Parameters
Defaults
Ifportstringisnotspecified,multipleauthenticationinformationwillbedisplayedforallports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaymultipleau thenticationinformationforportsge.3.14.The
numberof“Maxusers”shownbythiscommandvariesdependingontheplatform.
B5(rw)->show multiauth port ge.3.1-4
Port Mode Max Allowed Current
users users users
------------ ------------ ---------- ---------- ----------
ge.3.1 auth-opt n 1 0
ge.3.2 auth-opt n 10
ge.3.3 auth-opt n 10
ge.3.4 auth-opt n 10
set multiauth port
Usethiscommandtosetmultipleauthenticationpropertiesforoneormoreports.
Syntax
set multiauth port mode {auth-opt | auth-reqd | force-auth | force-unauth} |
numusers numusers port-string
portstring (Optional)Displaysmultipleauthenticationinformationforspecificport(s).