ip igmp startup-query-count
Enterasys B5 CLI Reference 13-15
Example
ThisexampleshowshowtosettheIGMPstartupqueryintervalto100secondsonVLAN1:
B5(su)->router(Config)#interface vlan 1
B5(su)->router(Config-if(Vlan 1))#ip igmp startup-query-interval 100
ip igmp startup-query-count
UsethiscommandtosetthenumberofIGMPqueriessentoutonstartup,separatedbythe
startupqueryintervalasdescribedinipigmpstartupqueryinterval(page1314).Thenoformof
thiscommandresetstheIGMPstartupquerycounttothedefaultvalueof2.
Syntax
ip igmp startup-query-count count
no ip igmp startup-query-count
Parameters
Defaults
None.
Mode
Interfaceconfiguration:B5(su)>router(Configif(Vlan1))#
Example
ThisexampleshowshowtosettheIGMPstartupquerycountto10onVLAN1:
B5(su)->router(Config)#interface vlan 1
B5(su)->router(Config-if(Vlan 1))#ip igmp startup-query-count 10
ip igmp last-member-query-interval
Usethiscommandtosetthemaximumresponsetimebeinginsertedintogroupspecificqueries
sentinresponsetoleavegroupmessages.ThenoformofthiscommandresetstheIGMPlast
memberqueryintervaltothedefaultvalueof1second.
Syntax
ip igmp last-member-query-interval time
no ip igmp last-member-query-interval
Parameters
Defaults
None.
count SpecifiesthenumberofIGMPstartupqueries.Validvaluesarefrom1to
20.Thedefaultvalueis2.
time SpecifiestheIGMPlastmemberqueryinterval.Validvaluesarefrom0to
255seconds.Thedefaultvalueis1second.