Considerations About Using Clear Config in a Stack
2-4 Configuring Switches in a Stack
Tocreateavirtualswitchconfigurationinastackenvironment:
1. Displaythetypesofswitchessupportedinthestack,usingtheshowswitchswitchtype
command(page26).
2. Usingtheoutputoftheshowswitchswitchtypecommand,determinetheswitchindex(SID)
ofthemodelofswitchbeingconfigured.
3. Addthevirtual
switchtothestackusingthesetswitchmembercommand(page210).Use
theSIDoftheswitchmodel,determinedintheprevious step,andtheunitIDthatyouwantto
assigntothisswitchmember.
4. Proceedtoconfiguretheportsofthevirtualswitchasyouwoulddo
forphysicallypresent
devices.
B5(su)->set vlan create 555
B5(su)->clear vlan egress 1 ge.2.1
B5(su)->set port vlan ge.2.1 555 untagged
B5(su)->show port vlan ge.2.1
ge.2.1 is set to 555
Considerations About Using Clear Config in a Stack
Whenusingtheclearconfigcommand(page3 50)toclearconfigurationparametersinastack,it
isimportanttorememberthefollowing:
•UseclearconfigtoclearconfigparameterswithoutclearingstackunitIDs.Thiscommand
WILLNOTclearstackparametersortheIPaddressandavoidstheprocessof
renumbering
thestack.
•Useclearconfigallwhenitisnecessarytoclearallconfigparameters,includingstackunit
IDsandswitchpriorityvalues.ThiscommandwillnotcleartheIPaddressnorwillitremove
anappliedadvancedfeaturelicense.
•UseclearipaddresstoremovetheIPaddressofthe
stack.
•Useclearlicensetoremoveanappliedlicensefromaswitch.
Configurationparametersandstackinginformationcanalsobeclearedonthemasterunitonly
byselectingthe“restoreconfigurationtofactorydefaults”optionfromthebootmenuonswitch
startup.Thisselectionwillleavestackingprioritiesonallother
units.
Note: If you preconfigure a virtual switch and then add a physical switch of a different type to the
stack as that unit number, any configured functionality that cannot be supported on the physical
switch will cause a configuration mismatch status for that device and the ports of the new device will
join detached. You must clear the mismatch before the new device will properly join the stack.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys b5 and is the answer not in the manual?

Enterasys b5 Specifications

General IconGeneral
BrandEnterasys
Modelb5
CategoryOther
LanguageEnglish