show spantree nonforwardingreason
9-54 Spanning Tree Configuration
show spantree nonforwardingreason
Usethiscommandtodisplaythereasonforplacingaportinanonforwardingstateduetoan
exceptionalcondition.
Syntax
show spantree nonforwardingreason port-string [sid sid]
Parameters
Defaults
Ifnoportstringisspecified,nonforwardingreasonisdisplayedforallports.
IfnoSIDisspecified,SID0isassumed.
Mode
Switchcommand,readonly.
Usage
Exceptionalconditionscausingaporttobeplacedinlis teningorblockingstateincludeaLoop
Protectevent,receiptofdisputedBPDUs,andloopbackdetection.
Example
Thisexampleshowshowtodisplaythenonforwardingreasononge.1.1:
B5(rw)->show spantree nonforwardingreason port ge.1.1
The non-forwarding reason for port
ge.1.1 on SID 0 is None
portstring Specifiesport(s)forwhichtodisplaythenonforwardingreason.
sidsid (Optional)SpecifiesthespecificSpanningTree(s)forwhichtodisplay
thenonforwardingreason.Validvaluesare0‐4094.Ifnotspecified,
SID0isassumed.

Table of Contents