set lldp tx-interval
Enterasys B5 CLI Reference 6-23
Defaults
Ifport‐stringisnotspecified,onlynon‐defaultvalueswillbedisplayedforallportsthathavenon‐
defaultvaluesconfigured.
Ifaport‐stringisspecified,thenallvalues,defaultandnon‐default,aredisplayedforthespecified
ports.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowshowtodisplayallLLDPnetworkpolicyinformationforge.1.1.
B5(ro)->show lldp port network-policy all ge.1.1
Ports Application State Tag Vlan-Id Cos Dscp
------- --------------------- -------- -------- ------- --- ---
ge.1.1 voice enabled untagged 1 0 0
voice signaling enabled untagged 1 0 0
guest voice enabled untagged 1 0 0
guest voice signaling enabled untagged 1 0 0
softphone voice enabled untagged 1 0 0
video conferencing enabled untagged 1 0 0
streaming video enabled untagged 1 0 0
video signaling enabled untagged 1 0 0
set lldp tx-interval
Usethiscommandtosetthetime,inseconds,betweensuccessiveLLDPframetransmissions
initiatedbychangesintheLLDPlocalsysteminformation.
Syntax
set lldp tx-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexamplesetsthetransmitintervalto20seconds.
port‐string (Optional)DisplaysinformationaboutLLDPnetworkpolicyfor
oneorarangeofports.
frequency SpecifiesthenumberofsecondsbetweentransmissionsofLLDP
frames.Valuecanrangefrom5to32,768seconds.Thedefaultis30
seconds.