set console baud
Enterasys B5 CLI Reference 3-31
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplayallconsolesettings:
B5(su)->show console
Baud Flow Bits StopBits Parity
------ ------- ---- ---------- ------
9600 Disable 8 1 none
set console baud
Usethiscommandtosettheconsoleportbaudrate.
Syntax
set console baud rate
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtosettheconsoleportbaudrateto19200:
B5(su)->set console baud 19200
Downloading a Firmware Image
YoucanupgradetheoperationalfirmwareintheEnterasysB5switchwithoutphysicallyopening
theswitchorbeinginthesamelocation.Therearetwowaystodownloadfirmwaretotheswitch:
•ViaTFTPdownload.ThisprocedureusesaTFTPserverconnectedtothenetworkand
downloadsthefirmwareusing the
TFTPprotocol.FordetailsonhowtoperformaTFTP
downloadusingthecopycommand,referto“copy”onpage3‐44.Forinformationonsetting
TFTPtimeoutandretryparameters,referto“settftptimeout”onpage3‐46and“settftp
retry”onpage3‐
47.
•Viatheserial(console)port.Thisprocedureisanout‐of‐bandoperationthatcopiesthe
firmwarethroughtheserialporttotheswitch.Itshouldbeusedincaseswhenyoucannot
connecttheswitchtoperformthein‐bandcopydownl oadprocedureviaTFTP.Serialconsole
downloadhas
beensuccessfullytestedwiththefollowingapplications:
–HyperTerminalCopyright1999
–TeraTermProVersion2.3
rate Setstheconsolebaudrate.Validvaluesare:1200,2400,4800,9600,19200,38400,
57600,and115200.