Configuring Policy Class of Service (CoS)
11-16 Policy Classification Configuration
Configuring Policy Class of Service (CoS)
TheEnterasysB5supportsClassofService(CoS),whichallowsyoutoassignmissioncriticaldata
toahigherprioritythroughthedevicebydelayinglesscriticaltrafficduringperiodsof
congestion.Thehigherprioritytrafficgoingthroughthedeviceisservicedfirst(beforelower
prioritytraffic).TheClassofService
capabilityofthedeviceisimplementedbyapriority
queueingmechanism.ClassofServiceisbasedontheIEEE802.1D(802.1p)standardspecification,
andallowsyoutodefineeightpriorities(07,with7grantedhighestpriority)andupto8transmit
queues(07)foreachport.
Bydefault,policy
basedCoSisdisabledonthedevice,anddefaultoruserassignedportbased
802.1D(802.1p)settingsareusedtodeterminetrafficprioritization.WhenpolicybasedCoSis
enabled,thedefaultanduserassignedpolicybasedsettingswilloverrideportbasedsettings
describedinChapter 12.
ClassofServicefunctionalitycan
alsobeusedtocontrolbroadcast,unknownunicast,and/or
multicastflooding.Thisfeaturepreventsconfiguredportsfrombeingdisruptedbyatrafficstorm
byratelimitingspecifictypesofpacketsthroughthoseports.RefertoAboutCoSBasedFlood
Controlonpage 1118formoreinformation.
About Policy-Based CoS Configurations
Onceenabledusingthesetcosstatecommand,youcanaddtothepolicybasedCoSfunctionby
definingnewportgroupings,andassigninginboundratelimiters.Theprocessforuserdefined
CoSconfigurationinvolvesthefollowingstepsandassociatedcommandslistedinProcedure 111.
Anexamplefollowstheprocedure.
Example
Thisexamplecreatesdifferentinboundratelimitersfortwoportgroupsandthenassignsthemto
trafficwithaCoSsettingof0.
1. Configuretwoportgroups,oneforuserportsandoneforuplinkportsandassignportstothe
groups.Portgroup1.0willrepresentuserports,group2.0
willrepresentuplinkports.
B5(su)->set cos port-config irl 1.0 name Users ports ge.1.1-46
B5(su)->set cos port-config irl 2.0 name Uplink ports ge.1.47-48
B5(su)->show cos port-config
Inbound Rate Limiting Port Configuration Entries
Note: It is recommended that you use Enterasys Networks NMS Policy Manager as an alternative
to CLI for configuring policy-based CoS on the switches.
Procedure 11-1 User-Defined CoS Configuration
Step Task Command(s)
1. Enable CoS set cos state enable
2. Create CoS IRL port groups set cos port-config irl
3. Define physical rate limiters for groups set cos port-resource irl
4. Create virtual reference for the IRL resource
(physical reference) for each port group
set cos reference
5. Add IRL reference to CoS settings table set cos settings

Table of Contents