clear system temperature
Enterasys B5 CLI Reference 3-19
Usage
Ontheplatformsthatsupportthisfeature,temperaturesensorsarelocatedinseveraldifferent
locationswithinthedevice.Thresholdcalibrationshavebeencalculatedseparatelyforeach
platform.Thethermalovertempthresholdisthehighwatermarkthat,whenreached,triggersan
alerttowarnthesystemadministratorthatthedeviceis
operatingathightemperatures.
Whenahightemperaturealertconditionoccurs,theCPULEDonthefrontpaneloftheswitch
willflashred.Inaddition,ifenabled,asyslogmessagewillbeloggedand/oranSNMPtrapwill
besent.
Thevaluessetwiththiscommandcanbeviewedwith
theshowsystemcommand.
Example
ThefollowingexampleenablessendingSNMPtrapsandsetstheovertempthresholdto60%.
B5(su)->set system temperature trap enable overtemp-threshold 60
clear system temperature
Usethiscommandtoresetsystemhightemperatureparameterstotheirdefaultvalues,onthe
platformsthatsupportthisfeature.
Syntax
clear system temperature
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thiscommandresetsallthehightemperatureparameterstotheirdefaultvalues:
•Syslogalertsaredisabledbydefault.
•Trapalertsaredisabledbydefault.
•Overtempthresholdis100%bydefault.
Example
Thisexampleresetsallhightemperatureparameterstotheirdefaults.
B5(su)->clear system temperature