Loading...
set logging application
14-8 Logging and Network Management
Parameters
Defaults
Iflevelisnotspecified,nonewillbeapplied.
Mode
Switchcommand,read‐write.
mnemonic Specifiesacasesensitivemnemonicabbreviation ofanapplicationtobe
logged.Thisparameterwillvarydependingonthenumberandtypesof
applicationsrunningonyoursystem.Todisplayacompletelist,usethe
showloggingapplicationcommandasdescribedin“showlogging
application”on
page 14‐6.Samplemnemonicsandtheircorresponding
applicationsarelistedinTable 14‐3onpage 14‐8.
Note: Mnemonic values are case sensitive and must be typed as they appear in
Table 14-3.
all Setstheloggingseveritylevelforallapplications.
levellevel (Optional)Specifiestheseveritylevelatwhichtheserverwilllog
messagesforapplications.Validvaluesandcorrespondinglevelsare:
1—emergencies(systemisunusable)
2—alerts(immediateactionrequired)
3—criticalconditions
4—errorconditions
5—warningconditions
6—notifications(significantconditions)
7—informationalmessages
8—debuggingmessages
Table 14-3 Mnemonic Values for Logging Applications
Mnemonic Application
CLIWEB Command Line Interface and Webview management
SNMP Simple Network Management Protocol
STP Spanning Tree Protocol
Driver Hardware drivers
System Non-application items such as general chassis management
Stacking Stacking management (if applicable)
UPN User Personalized Networking
Router Router