set cdp hold-time
SecureStack B3 Configuration Guide 4-5
set cdp hold-time
UsethiscommandtosettheholdtimevalueforCDPdiscoveryprotocolconfigurationmessages.
Syntax
set cdp hold-time hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCDPholdtimeto60seconds:
B3(su)->set cdp hold-time 60
clear cdp
UsethiscommandtoresetCDPdiscoveryprotocolsettingstodefaults.
Syntax
clear cdp {[state] [port-state port-string] [interval] [hold-time] [auth-code]}
Parameters
Defaults
Atleastoneoptionalparametermustbeentered.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheCDPstatetoautoenabled:
B3(su)->clear cdp state
holdtime SpecifiestheholdtimevalueforCDPmessagesinseconds.Validvaluesare
from15to600.
state (Optional)ResetstheglobalCDPstatetoauto enabled.
portstateportstring (Op tional)Resetstheportstateonspecificport(s)toautoenabled.
interval (Optional)Resetsthemessagefrequencyintervalto60seconds.
holdtime (Optional)Resetstheholdtimevalueto180seconds.
authcode (Optional)Resetstheauthenticationcodeto16
bytesof00(000000
0000000000).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals