EasyManuals Logo

Enterasys SecureStack B3 User Manual

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #519 background imageLoading...
Page #519 background image
show dot1x auth-config
SecureStack B3 Configuration Guide 20-11
Examples
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±802.1Xî ±status:î ±
B3(su)->show dot1x
DOT1X is disabled.
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±authenticationî ±diagnosticsî ±informationî ±forî ±ge.1.1:î ±
B3(su)->show dot1x auth-diag ge.1.1
Port : 1 Auth-Diag
Enter Connecting: 0
EAP Logoffs While Connecting: 0
Enter Authenticating: 0
Success While Authenticating 0
Timeouts While Authenticating: 0
Fails While Authenticating: 0
ReAuths While Authenticating: 0
EAP Starts While Authenticating: 0
EAP logoff While Authenticating: 0
Backend Responses: 0
Backend Access Challenges: 0
Backend Others Requests To Supp: 0
Backend NonNak Responses From: 0
Backend Auth Successes: 0
Backend Auth Fails: 0
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±authenticationî ±statisticsî ±forî ±ge.1.1:î ±
B3(su)->show dot1x auth-stats ge.1.1
Port: 1 Auth-Stats
EAPOL Frames Rx: 0
EAPOL Frames Tx: 0
EAPOL Start Frames Rx: 0
EAPOL Logoff Frames Rx: 0
EAPOL RespId Frames Rx: 0
EAPOL Resp Frames Rx: 0
EAPOL Req Frames Tx: 0
EAP Length Error Frames Rx: 0
Last EAPOL Frame Version: 0
Last EAPOL Frame Source: 00:00:00:00:00:00
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±theî ±statusî ±ofî ±portî ±reauthenticationî ±controlî ±forî ±ge.1.1î ±throughî ±
ge.1.6:î ±
B3(su)->show dot1x port reauth ge.1.1-6
Port 1: Port reauthenticate: FALSE
Port 2: Port reauthenticate: FALSE
Port 3: Port reauthenticate: FALSE
Port 4: Port reauthenticate: FALSE
Port 5: Port reauthenticate: FALSE
Port 6: Port reauthenticate: FALSE
show dot1x auth-config
Useî ±thisî ±commandî ±toî ±displayî ±802.1Xî ±authenticationî ±configurationî ±settingsî ±forî ±oneî ±orî ±moreî ±ports.
Syntax
show dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod]
[port-string]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals