show spantree lpwindow
SecureStack B3 Configuration Guide 7-47
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethresholdisreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120seconds:
B3(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectwindowvalue:
B3(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
clear spantree lpwindow
UsethiscommandtoresettheLoopProtecteventwindowtothedefaultvalueof180seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.