clear dot1x auth-config
SecureStack B3 Configuration Guide 20-15
clear dot1x auth-config
Usethiscommandtoreset802.1Xauthenticationparameterstodefaultvaluesononeormore
ports.
Syntax
clear dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod] [port-
string]
Parameters
Defaults
Ifnoparametersarespecified,allauthenticationparameterswillbereset.
Ifportstringisnotspecified,parameterswillbesetonallports.
Mode
Switchcommand,readwrite.
Examples
Thisexampleshowshowtoresetthe802.1Xportcontrolmodetoautoonallports:
B3(su)->clear dot1x auth-config authcontrolled-portcontrol
Thisexampleshowshowtoresetreauthenticationcontroltodisabledonportsge.1.13:
B3(su)->clear dot1x auth-config reauthenabled ge.1.1-3
Thisexampleshowshowtoresetthe802.1Xquietperiodto60secondsonportsge.1.13:
B3(su)->clear dot1x auth-config quietperiod ge.1.1-3
show eapol
UsethiscommandtodisplayEAPOLstatusorsettingsforoneormoreports.
authcontrolled
portcontrol
(Optional)Resetsthe802.1Xportcontrolmodetoauto.
maxreq (Optional)Resetsthe maximumrequestsvalueto2.
quietperiod (Optional)Resetsthequietperiodvalueto60seconds.
reauthenabled (Optional)Resetsthereauthenticationcontrolstatetodisabled
(false).
reauthperiod (Optional)Resetsthereauthenticationperiodvalueto3600seconds.
servertimeout (Optional)Resetstheservertimeoutvalueto30seconds.
supptimeout (Optional)Resetstheauthenticationsupplicanttimeoutvalueto30
seconds.
txperiod (Optional)Resetsthetransmissionperiodvalueto30seconds.
portstring (Optional)Resetssettingsonspecificport(s).Foradetailed
descriptionof
possibleportstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 51.