EasyManua.ls Logo

Enterasys SecureStack B3

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set summertime date
SecureStack B3 Configuration Guide 3-17
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtoenabledaylightsavingstimefunction:
B3(su)->set summertime enable
set summertime date
Usethiscommandtoconfigurespecificdatestostartandstopdayl ightsavingstime.These
settingswillbenonrecurringandwillhavetoberesetannually.
Syntax
set summertime date start_month start_date start_year start_hr_min end_month
end_date end_year end_hr_min [offset_minutes]
Parameters
Defaults
Ifanoffsetisnotspecified,nonewillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetadaylightsavingstimestartdateofApril4,2004at2a.m.andan
endingdateofOctober31,2004at2a.m.withanoffsettimeofonehour:
B3(su)->set summertime date April 4 2004 02:00 October 31 2004 02:00 60
set summertime recurring
Usethiscommandtoconfigurerecurringdaylightsavingstimesettings.Thesesettingswillstart
andstopdaylightsavingstimeatthespecifieddayofthemonthandhoureachyearand willnot
havetoberesetannually.
start_month Specifiesthemonthoftheyeartostartdaylightsavingstime.
start_date Specifies
thedayofthemonthtostartdaylightsavingstime.
start_year Specifies theyeartostartdaylightsavingstime.
start_hr_min Specifiesthetimeofdaytostartdaylightsavingstime.Formatishh:mm.
end_month Specifiesthemonthoftheyeartoenddaylightsavingstime.
end_date Specifiesthedayofthemonthto
enddaylightsavingstime.
end_year Specifiestheyeartoenddaylightsavingstime.
end_hr_min Specifiesthetimeofdaytoenddaylightsavingstime.Formatishh:mm.
offset_minutes (Optional)Specifiestheamountoftimeinminutestooffsetdaylight
savingstimefromthenondaylightsavingstimesystemsetting.Valid
valuesare1‐
1440.