set pwa initialize
SecureStack B3 Configuration Guide 20-65
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
PWAwilluseaguestpasswordandguestusernametograntnetworkaccesswithdefaultpolicy
privilegestouserswithoutestablishedloginnamesandpasswords.
Example
ThisexampleshowshowtoenablePWAguestnetworkingwithRADIUSauthentication:
B3(su)->set pwa guestnetworking authradius
set pwa initialize
UsethiscommandtoinitializeaPWAporttoitsdefaultunauthenticatedstate.
Syntax
set pwa initialize [port-string]
Parameters
Defaults
Ifportstringisnotspecified,allportswillbeinitialized.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoinitializeportsge.1.57:
B3(su)->set pwa initialize ge.1.5-7
authnone Enablesguestnetworkingwithnoauthentica tionmethod.
authradius EnablesguestnetworkingwithRADIUSauthentication.Uponsuccessful
authenticationfromRADIUS,PWAwillapplythepolicyreturnedfrom
RADIUStothePWAport.
disable Disablesguestnetworking.
portstring (Optional)Initializesspecificport(s).Foradetaileddescriptionofpossible
portstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 51.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals