EasyManuals Logo

Enterasys SecureStack B3 User Manual

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
show spantree adminedge
SecureStack B3 Configuration Guide 7-37
Parameters
Defaults
Ifsidisnotspecified,adminpathcostwillberesetforSpanningTree0.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresettheadminpathcostto0forge.3.2onSID1:
B3(su)->clear spantree adminpathcost ge.3.2 sid 1
show spantree adminedge
Usethiscommandtodisplaytheedgeportadministrativestatusforaport.
Syntax
show spantree adminedge [port port-string]
Parameters
Defaults
IfportstringisnotspecifiededgeportadministrativestatuswillbedisplayedforallSpanning
Treeports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.3.2:
B3(su)->show spantree adminedge port ge.3.2
Port ge.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
portstring Specifiestheport(s)forwhichtoresetadminpathcost.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntax
UsedintheCLIonpage 51.
sidsid (Optional)Resets
theadminpathcostforspecificSpanningTree(s).
Validvaluesare0‐4094.If notsp ecified,SID0isassumed.
portstring (Optional)Displaysedgeportadministrativestatusforspecific
port(s).Foradetaileddescriptionofpossibleportstringvalues,
refertoPortStringSyntaxUsedintheCLIonpage 51.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals