Loading...
show spantree adminedge
SecureStack B3 Configuration Guide 7-37
Parameters
Defaults
Ifsidisnotspecified,adminpathcostwillberesetforSpanningTree0.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresettheadminpathcostto0forge.3.2onSID1:
B3(su)->clear spantree adminpathcost ge.3.2 sid 1
show spantree adminedge
Usethiscommandtodisplaytheedgeportadministrativestatusforaport.
Syntax
show spantree adminedge [port port-string]
Parameters
Defaults
IfportstringisnotspecifiededgeportadministrativestatuswillbedisplayedforallSpanning
Treeports.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.3.2:
B3(su)->show spantree adminedge port ge.3.2
Port ge.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
portstring Specifiestheport(s)forwhichtoresetadminpathcost.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntax
UsedintheCLIonpage 51.
sidsid (Optional)Resets
theadminpathcostforspecificSpanningTree(s).
Validvaluesare0‐4094.If notsp ecified,SID0isassumed.
portstring (Optional)Displaysedgeportadministrativestatusforspecific
port(s).Foradetaileddescriptionofpossibleportstringvalues,
refertoPortStringSyntaxUsedintheCLIonpage 51.