set lldp port trap
4-26 Discovery Protocol Configuration
Mode
Switchcommand,readwrite.
Example
ThisexampleenablesbothtransmittingLLDPDUsandreceivingandprocessingLLDPDUsfrom
remotesystemsonports
ge.1.1throughge.1.6.
B3(rw)->set lldp port status both ge.1.1-6
set lldp port trap
UsethiscommandtoenableordisablesendingLLDPnotifications(traps)whenaremotesystem
changeisdetected.
Syntax
set lldp port trap {enable | disable} port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleenablestransmitting LLDPtrapsonportsge.1.1throughge.1.6.
B3(rw)->set lldp port trap enable ge.1.1-6
set lldp port med-trap
UsethiscommandtoenableordisablesendinganLLDPMEDnotificationwhenachangeinthe
topologyhasbeensensedontheport(thatis,aremoteendpointdevicehasbeenattachedor
removedfromtheport).
Syntax
set lldp port med-trap {enable | disable} port-string
Parameters
enable EnabletransmittingLLDPtrapsonthespecifiedports.
disable DisabletransmittingLLDPtrapsonthespecifiedports.
portstring Specifiestheportorrangeofportstobeaffected.
enable EnablestransmittingLLDPMEDtrapsonthespecifiedports.
disable DisablestransmittingLLDPMEDtrapsonthespecifiedports.
portstring Specifiestheportorrangeofportstobeaffected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals