clear snmp targetaddr
SecureStack B3 Configuration Guide 6-27
Defaults
Ifnotspecified,udpportwillbesetto162.
Ifnotspecified,maskwillbesetto255.255.255.255
Ifnotspecified,timeoutwillbesetto1500.
Ifnotspecified,numberofretrieswillbesetto3.
Iftaglistisnotspecified,nonewillbeset.
Ifnotspecified,storagetype
willbenonvolatile.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoconfigureatrapnotificationcalledTrapSink.”Thistrapnotification
willbesenttotheworkstation192.168.190.80(whichistargetaddress“tr”).Itwillusesecurityand
authorizationcriteriacontainedinatargetparametersentrycalled“v2cExampleParams”.For
moreinformationonconfiguringabasicSNMPtrap,
refertoCreatingaBasicSNMPTrap
Configurationonpage 636:
B3(su)->set snmp targetaddr tr 192.168.190.80 param v2cExampleParams taglist
TrapSink
clear snmp targetaddr
UsethiscommandtodeleteanSNMPtargetaddressentry.
Syntax
clear snmp targetaddr targetAddr
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearSNMPtargetaddressentry“tr”:
B3(su)->clear snmp targetaddr tr
targetAddr Specifiesthetargetaddressentrytodelete.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals