show mac agetime
SecureStack B3 Configuration Guide 13-19
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayMACaddressinformationforge.3.1:
B3(su)->show mac port ge.3.1
MAC Address FID Port Type
----------------- ---- ------------- --------
00-09-6B-0F-13-E6 15 ge.3.1 Learned
MAC Address VLAN Port Type Status Egress Ports
----------------- ---- ------------- ------- ------- ---------------------------
01-01-23-34-45-56 20 any mcast perm ge.3.1
Table 135providesanexplanationofthecommandoutput.
show mac agetime
UsethiscommandtodisplaythetimeoutperiodforaginglearnedMACentries.
Syntax
show mac agetime
Parameters
None.
Defaults
None.
Table 13-5 show mac Output Details
Output What It Displays...
MAC Address MAC addresses mapped to the port(s) shown.
FID Filter database identifier.
Port Port designation.
Type Address type. Valid types are:
Learned
•Self
Management
Other
mcast (multicast)
VLAN The VLAN ID configured for the multicast MAC address.
Status The status of the multicast address.
Egress Ports The ports which have been added to the egress ports list.