EasyManuals Logo

Enterasys SecureStack B3 User Manual

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #572 background imageLoading...
Page #572 background image
set pwa guestpassword
20-64 Security Configuration
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearthePWAguestusername
B3(su)->clear pwa guestname
set pwa guestpassword
UsethiscommandtosettheguestuserpasswordforPWAnetworking.
Syntax
set pwa guestpassword
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
PWAwillusethispasswordandtheguestusernametograntnetworkaccesstoguestswithout
establishedloginnamesandpasswords.
Example
ThisexampleshowshowtosetthePWAguestuserpasswordname:
B3(su)->set pwa guestpassword
Guest Password: *********
Retype Guest Password: *********
set pwa gueststatus
Usethiscommandtoenableordisableguestnetworkingforportwebauthentication.
Syntax
set pwa gueststatus {authnone | authradius | disable}