set lldp port location-info
SecureStack B3 Configuration Guide 4-27
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleenablestransmitting LLDPMEDtrapsonportsge.1.1throughge.1.6.
B3(rw)->set lldp port med-trap enable ge.1.1-6
set lldp port location-info
UsethiscommandtoconfigureLLDPMEDlocationinformationonaportorrangeofports.
Currently,onlyEmergencyCallServices(ECS)EmergencyLocationIdentificationNumber
(ELIN)issupported.
Syntax
set lldp port location-info elin elin-string port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Afteryouconfigurealocationinformationvalue,youmustalsoconfiguretheporttosendthe
LocationInformationTLVwiththesetlldpporttxtlvcommand.Thisexampleconfiguresthe
ELINidentifier5551234567onports
ge.1.1throughge.1.6andthenconfigurestheportstosend
theLocationInformationTLV.
B3(rw)->set lldp port location-info 5551234567 ge.1.1-6
B3(rw)->set lldp port tx-tlv med-loc ge.1.1-6
set lldp port tx-tlv
UsethiscommandtoselecttheoptionalLLDPandLLDPMEDTLVstobe transmittedin
LLDPDUsbythespecifiedportorports.Usetheshowlldpportlocalinfocommandtodisplay
thevaluesoftheseTLVsfortheport.
elin SpecifiesthattheECSELINdataformatistobe
used.
elinstring Specifiesthelocationidentifier.Valuecanbefrom10to25numerical
characters.
portstring Specifiestheportorrangeofportstobeaffected.

Table of Contents