EasyManuals Logo

Enterasys SecureStack B3 User Manual

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #253 background imageLoading...
Page #253 background image
show spantree backuproot
SecureStack B3 Configuration Guide 7-21
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtogloballyresetthebridgeforwarddelay:
B3(su)->clear spantree fwddelay
show spantree backuproot
UsethiscommandtodisplaythebackuprootstatusforanMSTinstance.
Syntax
show spantree backuproot [sid]
Parameters
Defaults
IfaSIDisnotspecified,thenstatuswillbeshownforSpanningTreeinstance0.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythestatusofthebackuprootfunctiononSID0:
B3(rw)->show spantree backuproot
Backup root is set to disable on sid 0
set spantree backuproot
UsethiscommandtoenableordisabletheSpanningTreebackuprootfunctionontheswitch.
Syntax
set spantree backuproot sid {disable | enable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
sid (Optional)DisplaybackuprootstatusforaspecificSpanningTree
identifier.Validvaluesare0‐4094.Ifnotspecified,SID0isassumed.
sid SpecifiestheSpanningTreeinstanceonwhichtoenableordisablethe
backuprootfunction.Validvaluesare0‐4094.
disable|enable Enablesordisablesthebackuprootfunction.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack B3 and is the answer not in the manual?

Enterasys SecureStack B3 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack B3
CategorySwitch
LanguageEnglish

Related product manuals