show policy profile
10-2 Policy Classification Configuration
Commands
show policy profile
Usethiscommandtodisplaypolicyprofileinformation.
Syntax
show policy profile {all | profile-index [consecutive-pids] [-verbose]}
Parameters
Defaults
Ifoptionalparametersarenotspecified,summaryinformationwillbedisplayedforthespecified
indexorallindices.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaypolicyinformationforprofile11:
B3(su)->show policy profile 11
Profile Index : 11
Profile Name : MacAuth1
Row Status : active
Port VID Status : Enable
Port VID Override : 11
CoS : 0
CoS Status : Disable
Egress Vlans : none
Forbidden Vlans : none
Untagged Vlans : none
Rule Precedence : 1-31
:MACSource(1),MACDest(2),Unknown(3),
:Unknown(4),Unknown(5),Unknown(6),
:Unknown(7),Unknown(8),Unknown(9),
:Unknown(10),Unknown(11),IPSource(12),
Note: B3, C3, and G3 devices support profile-based CoS traffic rate limiting only. Policy rules
specifying CoS will only rate limit on C2 and B2 devices, including when they are configured on
mixed stacks containing B3 and C3 devices.
For information about... Refer to page...
show policy profile 10-2
set policy profile 10-3
clear policy profile 10-5
all|profileindex Displayspolicyinformationforallprofileindexesoraspecificprofileindex.
consecutivepids (Optional)Displaysinformationforspecifiedconsecutiveprofileindexes.
verbose (Optional)Displaysdetailedinformation.