EasyManua.ls Logo

Enterasys SecureStack B3 - Set Logging Application; Show Logging Application Output Details

Enterasys SecureStack B3
582 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set logging application
SecureStack B3 Configuration Guide 13-7
Example
ThisexampleshowshowtodisplaysystemlogginginformationpertainingtotheSNMP
application.
B3(ro)->show logging application SNMP
Application Current Severity Level
---------------------------------------------
90 SNMP 6
1(emergencies) 2(alerts) 3(critical)
4(errors) 5(warnings) 6(notifications)
7(information) 8(debugging)
Table 13‐2providesanexplanationofthecommandoutput.
set logging application
Usethiscommandtosettheseverityleveloflogmessagesforoneorallapplications.
Syntax
set logging application {[mnemonic | all]} [level level]
Parameters
Table 13-2 show logging application Output Details
Output... What it displays...
Application A mnemonic abbreviation of the textual description for
applications being logged.
Current Severity Level Severity level at which the server is logging messages for the
listed application. This range (from 1 to 8) and its associated
severity list is shown in the CLI output. For a description of these
entries, which are set using the set logging application
command, refer to “set logging application” on page 13-7.
mnemonic Specifiesacasesensitivemnemonicabbreviationofanapplicationtobe
logged.Thisparameterwillvarydependingonthenumberandtypesof
applicationsrunningonyoursystem.Todisplayacompletelist,usethe
showloggingapplicationcommandasdescribedin“showlogging
application”onpage 13‐6.Sample
mnemonicsandtheircorresponding
applicationsarelistedinTable 13‐3onpage 13‐8.
Note: Mnemonic values are case sensitive and must be typed as they appear in
Table 13-3.
all Setstheloggingseveritylevelforallapplications.

Table of Contents