EasyManua.ls Logo

Enterasys SecureStack B3

Enterasys SecureStack B3
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
show port inlinepower
SecureStack B3 Configuration Guide 3-33
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePoEtrap messagingonmodule1:
B3(su)->set inlinepower trap enable 1
show port inlinepower
UsethiscommandtodisplayallportssupportingPoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPoEinformationforportge.2.1.Inthiscase,theport’s
administrativestate,PoEpriorityandclasshavenotbeenchangedfromdefaultvalues:
B3(su)->show port inlinepower ge.2.1
Port Type Admin Oper Priority Class Power(W)
---- ---- ----- ---- -------- ----- --------
ge.2.1 wireless auto searching low 0 360
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
disable|enable DisablesorenablesPoEtrapmessaging.
modulenumber Specifiesthemoduleonwhichtodisableorenabletrapmessaging.
portstring (Optional)DisplaysinformationforspecificPoEport(s).

Table of Contents

Related product manuals