show system hardware
3-12 Basic Configuration
Example
Thisexampleshowshowtodisplaysysteminformation:
B3(su)->show system
System contact:
System location:
System name:
Primary PS Status Secondary PS Status
----------------- -------------------
Ok Not Installed
Fan1-Status Fan2-Status
----------- -----------
Ok Ok
Fan3-Status
-----------
Ok
Thermal Sensor 1
----------------
+28 degrees Celsius (82 degrees Fahrenheit)
Thermal Sensor 2
----------------
+31 degrees Celsius (87 degrees Fahrenheit)
Uptime d,h:m:s Logout
-------------- -------
0,0:26:52 3 min
Table 3‐2providesanexplanationofthecommandoutput.
show system hardware
Usethiscommandtodisplaythesystem’shardwareconfiguration.
Syntax
show system hardware
Table 3-2 show system Output Details
Output What It Displays...
System contact Contact person for the system. Default of a blank string can be changed with the
set system contact command (“set system contact” on page 3-23).
System location Where the system is located. Default of a blank string can be changed with the
set system location command (“set system location” on page 3-22).
System name Name identifying the system. Default of a blank string can be changed with the
set system name command (“set system name” on page 3-22).
Primary PS Status Operational status for the primary power supply.
Fan Status Operational status of the fan trays.
Thermal Sensor Temperature reading from thermal sensor(s).
Uptime d,h:m:s System uptime.
Logout Time an idle console or Telnet CLI session will remain connected before timing
out. Default of 5 minutes can be changed with the set logout command (“set
logout” on page 3-25).